MDOT Table 909-7 Wall Thickness Requirements in Millimeters, Based on Diameter, Class of Pipe and Size of Corrugation.*

Diameter of Pipe 0 to 3 m Cover over 3 to 5 m Cover over 5 to 7 m Cover over 7 to 10 m Cover
Size of Corrugation (in. & mm) Size of Corrugation (in. & mm) Size of Corrugation (in. & mm) Size of Corrugation (in. & mm)
mm in 2 2/3 x 1/2
68 x 13
3 x 1
76 x 25
5 x 1
125 x 25
2 2/3 x 1/2
68 x 13
3 x 1
76 x 25
5 x 1
125 x 25
2 2/3 x 1/2
68 x 13
3 x 1
76 x 25
5 x 1
125 x 25
2 2/3 x 1/2
68 x 13
3 x 1
76 x 25
5 x 1
125 x 25
300 12" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
375 15" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
450 18" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
525 21" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
600 24" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
750 30" 1.63 - - 1.63 - - 1.63 - - 1.63 - -
900 36" 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63(1) 1.63 1.63
1050 42" 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63
1200 48" 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63 1.63(1) 1.63 1.63
1350 54" 2.01 1.63 1.63 2.01 1.63 1.63 2.01 1.63 1.63 2.01 1.63 1.63
1500 60" 2.77 1.63 1.63 2.77 1.63 1.63 2.77 1.63 1.63 2.77 1.63(1) 1.63
1650 66" 3.51 1.63 1.63 3.51 1.63 1.63 3.51 1.63 1.63 3.51 1.63(1) 1.63
1800 72" 4.27 1.63 1.63 4.27 1.63 1.63 4.27 1.63(1) 1.63 4.27 1.63(1) 1.63
1950 78" 4.27 1.63 1.63 4.27 1.63 1.63 4.27 1.63(1) 1.63 4.27 1.63(2) 1.63
2100 84" 4.27 1.63 1.63 4.27 1.63 1.63 4.27 1.63(1) 1.63 4.27 1.63(2) 2.01
2250 90" - 1.63 1.63 - 1.63 1.63 - 1.63(2) 1.63 - 2.01(1) 2.01
2400 96" - 2.01 2.01 - 2.01 2.01 - 2.01(1) 2.01 - 2.01(1) 2.01
2550 102" - 2.01 2.01 - 2.01 2.01 - 2.01(1) 2.01 - 2.01(1) 2.77
2700 108" - 2.77 2.77 - 2.77 2.77 - 2.77 2.77 - 2.77(1) 2.77
2850 114" - 2.77 2.77 - 2.77 2.77 - 2.77 2.77 - 2.77(1) 2.77
3000 120" - 2.77 2.77 - 2.77 2.77 - 2.77 2.77 - 2.77(1) 2.77
3150 126" - 3.51 3.51 - 3.51 3.51 - 3.51 3.51 - 3.51 3.51
3300 132" - 3.51 3.51 - 3.51 3.51 - 3.51 3.51 - 3.51(1) 3.51
3450 138" - 3.51 3.51 - 3.51 3.51 - 3.51 3.51 - 3.51(1) 3.51
3600 144" - 4.27 4.27 - 4.27 4.27 - 4.27 4.27 - 4.27(3) 4.27
(1) Increase the wall thinckness by one gage for riveted longitudinal seams.
(2) Increase the wall thickness by two gages for riveted longitudinal seams.
(3) Denotes Not Allowed for riveted longitudinal seams.
Riveted seams will not be permitted for 123mm x 25 mm corrugations.